Platform Calibration Kits
Platform calibration kits enhance the board population process by fine-tuning accuracy and repeatability capabilities. While an 0805 chip may not require the same accuracy as a 4 mil bump CSP, inaccurate placements still create a set of common issues - decreased product yield, increased board rework, and increased product costs. Incorporating a calibration routine ensures accurate placements over time, thereby maximizing yield, minimizing rework and reducing costs.
Calibration Placement Enhancement (CPE) reduces calibration time for placement heads and inspection camera, in addition to enhancing GSM accuracy and repeatability
Part Number 47383801
- Improves the mean placement accuracy after a successful calibration
- Restores accuracy specifications after a camera has been accidentally bumped
- Decreases calibration time required after removing and replacing heads
- Minimizes calibration time requirements and physically moving a GSM
Capability Assessment kit verifies placement accuracy and provides data for possible GSM placement adjustments
Part Number 45931001
- Verifies accuracy by examining ideal glass components placed by the GSM onto an ideal glass board with the included microscope
- System accuracy has been determined to be +/- 2m in X Y as measured on a View Precis 3000
- Analyze and potentially apply the results for accuracy adjustments
Calibration Kit - Staged Board Handling
Part Number 45235205
- Verifies the location and magnification of all GSM Cameras, as well as spindle locations
- Automated calibration routine which eliminates user intervention
- Verifies Pattern Error Correction and Inspection camera locations
- Determines spindle behavior at various rotations, ensuring accuracy
Calibration Kit - Dual Lane Board Handling
Part Number 45235204
Quick Calibration Solution Reference
 | Std Calibration | CPE | Capability Assessment |
| Perform Calibration | X | . | . |
| Measure Accuracy | . | X | X |
| Measure Repeatability | . | X | X |
| Adjust Mean Placement | . | X | . |
| Re-Calibrate Heads | . | X | . |
| Re-Calibrate Cameras | . | X | . |
Specifications
 | Time | Comments |
| Standard Calibration System | 1.5 to 3 hour procedure | Configuration Dependant |
| Capability Assessment System | 4 to 8 hour procedure | Configuration Dependant |
| CPE System | 30 minute routine | Must fully calibrate GSM* |
| GSM Accuracy Specification | 50.0m @ 5s; Cp>1.67 | Based on Flex Head |
| GSMx Accuracy Specification | 30.0m @ 5s; Cp>1.67 | Based on Flex Head |
| GSMx Accuracy Specification | 17.5m @ 5s; Cp>1.67 | Based on UFP Head |
*Note: Must perform the standard calibration prior to using CPE
For more information, contact a Universal Sales Rep. |
|